Z4A

Z4A - Force Transducer with Maximum Accuracy for use as Calibration Standard

Z4A force transducers comply even with the most demanding accuracy requirements. A DKD calibration can be made on request to account for the transducer’s optimum classification according to EN 10002-3 (version Z4A-G) (class 00, class 05 for 500kN).

The transducers are to be used for high precision measurements of tensile and compressive forces and for force comparison measurements (force standard). One additional feature is the innovative compensation method enabling bending moments and the effects of transverse forces to be minimised.

The Z4A is also fit for industrial applications, and may be used, e.g., if one transducer enables several force ranges to be covered, thus, saving the time and cost for transducer replacement. The transducers are available for several nominal measuring ranges in steps from 0...20kN to 0...500kN.

Max. operating force [%]

150

Nominal temp. range [°C]

+10...+40

Protection system

IP 67

Material

tempered steel

Direction of force

tensile / compressive

Nominal force

20 kN, 50 kN, 100 kN, 200 kN, 500 kN

Nominal sensitivity [mV/V]

2

Product Literature

Vänligen ange din epostadress.

Logga in här med hjälp av din epostadress om du redan har ett konto på HBM.com och få tillgång till HBMs kompletta tekniska dokumentation.

Product Literature

Z4A
Z4A ENDEESFRITPTCNJPKRRU
Data Sheet Please Log InPlease Log InPlease Log InPlease Log In
Mounting instructions Please Log InPlease Log InPlease Log InPlease Log In
Please Log InPlease Log In
Brochure Please Log InPlease Log InPlease Log In
CE-Declaration of Conformity Please Log InPlease Log InPlease Log In

Candid data sheets: We keep our promises.

Precision in series: This also applies to the accuracy of the values specified in our data sheets. Ideal conditions can often be theoretically attained based on the values given, but our data sheets focus on realistic standard assumptions - such as those likely to be encountered in your application. Therefore, please consider this when comparing our data sheets with those of other manufacturers.

Request a Quote

Få en offert för Z4A

Tack för att du visat intresse för HBMs produkter. Med hjälp av detta formulär kan du enkelt skicka din offertförfrågan.


Key Features

  • Force transducer with maximum accuracy for use as calibration standard
  • Classification option by device classes with DKD calibration certificate according to ISO 376
  • Transfer standard in international force reference
  • Force standard + DKD calibration certificate from HBM
  • Good long-term stability

Order Numbers

1-Z4A/20KN
1-Z4A/50KN
1-Z4A/100KN
1-Z4A/200KN
1-Z4A/500KN