See All Software See All Instruments See All Transducers See All Vibration Testing Equipment See All Electroacoustics See All Acoustic End-of-Line Test Systems See All Academy See All Resource Center See All Applications See All Industries See All Services See All Support See All Our Business See All Our History See All Global Presence
arrow_back_ios

Main Menu

See All Analysis & Simulation Software See All DAQ Software See All Drivers & API See All Utility See All Vibration Control See All High Precision and Calibration Systems See All DAQ Systems See All S&V Hand-held Devices See All Industrial Electronics See All Power Analyzer See All S&V Signal Conditioner See All Acoustic Transducers See All Current and Voltage Sensors See All Displacement Sensors See All Force Sensors See All Load Cells See All Multi Component Sensors See All Pressure Sensors See All Strain Sensors See All Strain Gauges See All Temperature Sensors See All Tilt Sensors See All Torque Sensors See All Vibration See All Accessories for Vibration Testing Equipment See All Vibration Controllers See All Measurement Exciters See All Modal Exciters See All Power Amplifiers See All LDS Shaker Systems See All Test Solutions See All Actuators See All Combustion Engines See All Durability See All eDrive See All Production Testing Sensors See All Transmission & Gearboxes See All Turbo Charger See All Training Courses See All Acoustics See All Asset & Process Monitoring See All Custom Sensors See All Durability & Fatigue See All Electric Power Testing See All NVH See All Reliability See All Vibration See All Weighing See All Automotive & Ground Transportation See All Calibration See All Installation, Maintenance & Repair See All Support Brüel & Kjær See All Release Notes See All Compliance
arrow_back_ios

Main Menu

See All nCode - Durability and Fatigue Analysis See All ReliaSoft - Reliability Analysis and Management See All API See All Experimental Testing See All Electroacoustics See All Noise Source Identification See All Environmental Noise See All Sound Power and Sound Pressure See All Noise Certification See All Industrial Process Control See All Structural Health Monitoring See All Electrical Devices Testing See All Electrical Systems Testing See All Grid Testing See All High-Voltage Testing See All Vibration Testing with Electrodynamic Shakers See All Structural Dynamics See All Machine Analysis and Diagnostics See All Dynamic Weighing See All Vehicle Electrification See All Calibration Services for Transducers See All Calibration Services for Handheld Instruments See All Calibration Services for Instruments & DAQ See All On-Site Calibration See All Resources See All Software License Management

Cost-optimized construction of subsea pipelines

Mitsui babcock, scotland

Testing of subsea oil pipelines

Mitsui Babcock, of Glasgow in Scotland, is a global leader in the validation and testing of subsea oil pipelines. This guarantees optimum pipeline construction, as well as safe laying even in deep sea. To derive the maximum possible benefit from their tests, they decided to use linear strain gages from HBM’s standard product program, the MGCplus amplifier system and the data analysis software catman.

Ensuring integrity under load …

A common method used in pipeline construction is to fit an enclosed stainless steel coating into the external carbon steel pipe by hydraulic widening. When the pipelines are laid, they are exposed to bending moments and transverse forces, whereas later on, they must withstand temperatures and pressures, for example, that must not be allowed to impair their function.

It is particularly important to test the loading capacity of the pipelines, to prevent subsequent damage that could have far greater effects on production and the environment. "One reason for using HBM’s MGCplus amplifier system is that it gives us access to significantly more measurement channels than were previously available for determining stress levels." Albert Holt, principal test engineer at Mitsui Babcock

 

… with HBM strain gages, MGCplus and catman to 35 MPa.

Pipeline sections up to 12 m in length are tested on a four-point bending rig designed by Mitsui Babcock. The duration of the tests varies, depending on the complexity of the test program. The latest technology is used to optimize the information obtained from the tests. For example, extremely high resolution cameras are inserted into the body of the pipe to provide visual evidence of possible structural damage, such as that occurring at the onset of buckling. The largest pipe tested by Mitsui Babcock was 660 mm in diameter. "HBM was a great help, as they developed a customized interface just for us. It allowed our engineers to see for themselves the effects of a pipeline bending under load. catman is the perfect tool for this." Albert Holt Most of the tests are static, it is only when testing to destruction with compression, tensile force and burst testing that dynamic tests are performed. Strain gages are used to determine the levels of strain that for static tests is 3% above nominal strain. The pipes are exposed to temperatures up to 165 °C and pressures up to 35 MPa. "HBM’s equipment is quickly configured and we can connect vast numbers of transducers. This clearly represents the best value for money." Albert Holt