See All Software See All Instruments See All Transducers See All Vibration Testing Equipment See All Electroacoustics See All Acoustic End-of-Line Test Systems See All Academy See All Resource Center See All Applications See All Industries See All Services See All Support See All Our Business See All Our History See All Global Presence
arrow_back_ios

Main Menu

See All Analysis & Simulation Software See All DAQ Software See All Drivers & API See All Utility See All Vibration Control See All High Precision and Calibration Systems See All DAQ Systems See All S&V Hand-held Devices See All Industrial Electronics See All Power Analyzer See All S&V Signal Conditioner See All Acoustic Transducers See All Current and Voltage Sensors See All Displacement Sensors See All Force Sensors See All Load Cells See All Multi Component Sensors See All Pressure Sensors See All Strain Sensors See All Strain Gauges See All Temperature Sensors See All Tilt Sensors See All Torque Sensors See All Vibration See All Accessories for Vibration Testing Equipment See All Vibration Controllers See All Measurement Exciters See All Modal Exciters See All Power Amplifiers See All LDS Shaker Systems See All Test Solutions See All Actuators See All Combustion Engines See All Durability See All eDrive See All Production Testing Sensors See All Transmission & Gearboxes See All Turbo Charger See All Training Courses See All Acoustics See All Asset & Process Monitoring See All Custom Sensors See All Durability & Fatigue See All Electric Power Testing See All NVH See All Reliability See All Vibration See All Weighing See All Automotive & Ground Transportation See All Calibration See All Installation, Maintenance & Repair See All Support Brüel & Kjær See All Release Notes See All Compliance
arrow_back_ios

Main Menu

See All nCode - Durability and Fatigue Analysis See All ReliaSoft - Reliability Analysis and Management See All API See All Experimental Testing See All Electroacoustics See All Noise Source Identification See All Environmental Noise See All Sound Power and Sound Pressure See All Noise Certification See All Industrial Process Control See All Structural Health Monitoring See All Electrical Devices Testing See All Electrical Systems Testing See All Grid Testing See All High-Voltage Testing See All Vibration Testing with Electrodynamic Shakers See All Structural Dynamics See All Machine Analysis and Diagnostics See All Dynamic Weighing See All Vehicle Electrification See All Calibration Services for Transducers See All Calibration Services for Handheld Instruments See All Calibration Services for Instruments & DAQ See All On-Site Calibration See All Resources See All Software License Management

Overload protection - good protection for load cells

The accuracy class of a load cell always refers to its maximum capacity. The load cells cannot be over-dimensioned up to any extent, dependent on the required scale accuracy and the smallest portions to be measured, as the absolute measurement error is directly proportional to the maximum capacity. The constructive outlay of a specially designed overload protection is always justifiable when the load cells need to be loaded up to their maximum capacity, where the risk of overload is always present. Overload protection should be provided to protect load cells in the following typical cases:
  • The maximum loads of the load cells are not known.
  • If strongly dynamic loads, e.g. falling product to be weighed (pulse loading), are to be expected.
Protecting load cells against overload is frequently achieved by over-dimensioning them. If the overload protection is actually achieved through this, no additional expenditure is necessary.

Load cells with mechanical stop


Practice shows that load cells with smaller maximum capacities are often more frequently overloaded than load cells with high maximum capacity ranges. For example, a load cell with a maximum capacity of 20 kg can be significantly damaged simply by a falling wrench. The designer can also realize and implement their own individual overload protection for a series of load cell geometries. Figure 1 shows a design proposal for an overload protection for the HBM load cell type Z6. The possible deflection/travel of the load cell is limited here by a mechanical stop. The data sheet data nominal (rated) displacement describes the deformation value of the load cell at nominal (rated) loading. The possible travel, dependent on the load cell type and its maximum capacity range, is limited by a mechanical stop to 120 - 150% of the nominal (rated) displacement in order to prevent an overload of the load cell. The stop is adjusted here with distance gauges. As the described deformations are very low - in practice just several 1/10 mm - fine thread screws that can be tensioned have been proven to be suitable. It is also recommended that the gap between load cell and stop is protected against contamination; because contamination can also be a cause for measurement errors such as unwanted travel limitation. Displacement different to that specified in the data sheet may arise if the load cell support structure is soft. The overload protection frequently occurs too early because the mounting plate is bending. The gap between load cell and stop must therefore be increased. It is advantageous here for the user to be able to load the weighing device with the maximum capacity and then set the remaining gap to the mechanical stop from 0.05 to 0.1 mm.

Pretensioned spring packages


Another form of overload protection is offered by pretensioned spring packages integrated in the force flow (Figure 2). If the maximum capacity exceeds a specific value, the spring is compressed and applies the force, via a suitable construction, to a mechanical stop. The gap width is significantly wider with this form of overload protection. This makes the setting of the permissible loads simpler and more reliable. In addition, the spring properties crucially reduce the risk of load cell damage from pulse loading. Due to the low contamination sensitivity of these spring packages, the constructive and material outlay can be easily justified in a series of applications, compared to other forms of overload protection.

Transit protection devices

It is recommended that suitable transit protection devices are provided for weighing technology systems to protect the load cell. Vibrations during transport can also lead to the described, partly extreme pulse loading of the load cells and therefore to their failure. Where possible, load cells should only be mounted at the final installation site of the system. In this case, a placeholder should be inserted in the system in place of the load cell. Dummies with the same external dimension of the load cell have been proven to be suitable. If this is not possible, thick sheet metal can also be used in this case as intentional force shunts.