LY: Linear Strain Gauges with 1 Measuring Grid

Series LY is the first choice for strain measurements in only one direction. With types LY1, LY2, LY4, LY5, LY6, LY7 and LY8 we offer you linear strain gauges (SGs) in various geometries and sizes, each available with temperature responses adapted for steel, aluminum or to customer specification. Strain gauges are available with nominal (rated) resistances of 120, 350, 700 and 1000 ohms.

The measuring grid consists of constantan; the material of the measuring grid carrier is polyimide. While we offer a wide selection of products, they all have one thing in common: the excellent properties of HBM Y series strain gauges:

  • Universal strain gauge with excellent properties
  • Various connection configurations available, including version with practical connection cable
  • Flexible and easy to work with.

LY4 strain gauges also come with a connection cable! 

 

Ordering number 

Nominal (rated) resistance

Dimensions [mm/inch]

Vmax 

Solder terminals

Preferred types

Measuring grid

Carrier

Ω

a

b

c

d

 

1-LY1x-0.3/120 

120

0.3
0.012

0.9
0.035

2
0.079

1.2
0.047

0.6

LS7

1

1-LY1x-0.6/120 

120

0.6
0.024

1
0.039

5
0.197

3.2
0.126

1.5

LS7

1, 3

1-LY1x-1.5/120

120

1.5
0.059

1.2
0.047

6.5
0.256

4.7
0.185

2.5

LS7

1, 3

1-LY1x-3/120    

120

3
0.118

1.6
0.063

8.5
0.335

4.5
0.177

4

LS7

1, 3

1-LY1x-3/120A 

120

3
0.118

1.6
0.063

8.5
0.335

4.5
0.177

4

LS7

1

1-LY1x-6/120

120

6
0.236

2.7
0.106

13
0.512

6
0.236

8

LS5

1, 3

1-LY1x-6/120A 

120

6
0.236

2.7
0.106

13
0.512

6
0.236

8

LS5

1

1-LY1x-10/120

120

10
0.394

4.6
0.181

18.5
0.728

9.5
0.374

13

LS5

1, 3

1-LY1x-10/120A 

120

10
0.394

4.6
0.181

18.5
0.728

9.5
0.374

13

LS5

1

1-LY1x-1.5/350

350

1.5
0.059

1.2
0.047

5.7
0.224

4.7
0.185

4.5

LS7

1, 3

1-LY1x-3/350

350

3
0.118

1.6
0.063

8.5
0.335

4.5
0.177

7

LS7

1, 3

1-LY1x-3/350A

350

3
0.118

1.6
0.063

8.5
0.335

4.5
0.177

7

LS7

-

1-LY1x-6/350

350

6
0.236

2.8
0.11

13
0.512

6
0.236

13

LS5

1, 3

1-LY1x-6/350A 

350

6
0.236

2.8
0.11

13
0.512

6
0.236

13

LS5

-

1-LY1x-10/350

350

10
0.394

5.0
0.197

18.5
0.728

9.5
0.374

23

LS5

1

1-LY1x-10/350A 

350

10
0.394

5.0
0.197

18.5
0.728

9.5
0.374

23

LS5

-

 

Ordering number

Nominal (rated) resistance

Dimensions [mm/inch]

Vmax 

Solder terminals

Preferred types

Measuring grid

Carrier

Ω

a

b

c

d

1-LY2x-0.6/120

120

0.6
0.024

0.6
0.024

3.5
0.138

6.4
0.252

1

LS7

1

1-LY2x-1.5/120

120

1.5
0.059

1.5
0.059

4.7
0.185

8.3
0.327

2

LS5

-

1-LY2x-3/120 

120

3
0.118

2.8
0.11

7.5
0.295

10
0.394

6

LS5

1

1-LY2x-6/120

120

6
0.236

6
0.236

11
0.433

16
0.63

12

LS4

-

 

Ordering number

Nominal (rated) resistance

Dimensions [mm/inch]

Vmax

Solder terminals

 

 

Preferred types

Measuring grid

Carrier

Ω

a

b

c

d

1-LY4x-0.6/120

120

0.6
0.024

1.1
0.043

6
0.236

4
0.157

1.5

LS5

1

1-LY4x-1.5/120

120

1.5
0.059

1.2
0.047

7
0.276

5
0.197

2.5

LS5

1

1-LY4x-3/120

120

3
0.118

1.2
0.047

8
0.315

5
0.197

3.5

LS5

1, 3

1-LY4x-3/120A

120

3
0.118

1.2
0.047

8
0.315

5
0.197

3.5

LS5

-

1-LY4x-6/120

120

6
0.236

2.7
0.106

13.9
0.547

5.9
0.232

8

LS5

1, 3

1-LY4x-6/120A

120

6
0.236

2.7
0.106

13.9
0.547

5.9
0.232

8

LS5

1

1-LY4x-10/120

120

10
0.394

4.9
0.193

18
0.709

8
0.315

14

LS5

1

1-LY4x-10/120A

120

10
0.394

4.9
0.193

18
0.709

8
0.315

14

LS5

-

1-LY4x-20/120

120

20
0.787

0.5
0.02

31.8
1.252

8.2
0.323

6.5

LS5

1

1-LY4x-50/120

120

50
1.969

0.8
0.031

63.6
2.504

8.2
0.323

12

LS5

1

1-LY4x-100/120

120

100
3.937

1
0.039

114.8
4.520

8.2
0.323

19

LS5

1

1-LY4x-150/120

120

150
5.906

1.2
0.047

165.6
6.520

8.2
0.323

25

LS5

1

1-LY4x-1.5/350

350

1.5
0.059

2.3
0.091

9.2
0.362

5.9
0.232

6.5

LS5

1

1-LY4x-3/350

350

3
0.118

2.5
0.098

10.9
0.429

5.9
0.232

9

LS5

1, 3

1-LY4x-3/350A

350

3
0.118

2.5
0.098

10.9
0.429

5.9
0.232

9

LS5

1

1-LY4x-6/350

350

6
0.236

2.8
0.110

13.9
0.547

5.9
0.232

15

LS5

1, 3, 6

1-LY4x-6/350A

350

6
0.236

2.8
0.110

13.9
0.547

5.9
0.232

15

LS5

-

1-LY4x-10/350

350

10
0.394

5
0.197

18
0.709

8
0.315

24

LS5

1

1-LY4x-10/350A

350

10
0.394

5
0.197

18
0.709

8
0.315

24

LS5

-

1-LY4x-3/700

700

3
0.118

2.7
0.106

10.9
0.429

5.9
0.232

13

LS5

1, 3

1-LY4x-6/700   

700

6
0.236

4.1
0.161

13.9
0.547

5.9
0.232

23

LS5

1

1-LY4x-10/700

700

10
0.394

5
0.197

18
0.709

8
0.315

33

LS5

-

1-LY4x-3/1000

1.000

3
0.118

2.7
0.106

10.9
0.429

5.9
0.232

16

LS5

-

1-LY4x-6/1000

1.000

6
0.236

4.2
0.165

13.9
0.547

5.9
0.232

27

LS5

1

1-LY4x-10/1000

1.000

10
0.394

5
0.197

18
0.709

8
0.315

40

LS5

-

 

Ordering number

Nominal (rated) resistance

Dimensions [mm/inch]

Vmax

Solder terminals

Preferred types

Measuring grid

Carrier

Ω

a

b

c

d

1-LY5x-3/120

120

3
0.118

0.4
0.016

9
0.354

4.7
0.185

2

LS7

-

1-LY5x-6/120

120

6
0.236

0.4
0.016

13
0.512

4.7
0.185

3

LS7

-

 

Ordering number

Nominal (rated) resistance

Dimensions [mm/inch]

Vmax

Solder terminals

 

 

Preferred types

Measuring grid

Carrier

Ω

a

b

c

d

1-LY6x-1.5/120

120

1.5
0.059

1.0
0.039

7.8
0.307

4.7
0.185

2.5

-

1

1-LY6x-3/120  

120

3
0.118

1.5
0.059

9.8
0.386

4.7
0.185

4

-

1

1-LY6x-3/120A

120

3
0.118

1.5
0.059

9.8
0.386

4.7
0.185

4

-

-

1-LY6x-6/120

120

6
0.236

2.7
0.106

16
0.63

6.3
0.248

8

-

1, 3

1-LY6x-6/120

120

6
0.236

2.7
0.106

16
0.63

6.3
0.248

8

-

-

1-LY6x-10/120

120

10
0.394

4.6
0.181

23.5
0.925

9.3
0.366

13

-

1

1-LY6x-3/350A

350

3
0.118

1.6
0.063

9.8
0.386

4.7
0.185

7

-

-

1-LY6x-3/350

350

3
0.118

1.6
0.063

9.8
0.386

4.7
0.185

7

-

1

1-LY6x-6/350A

350

6
0.236

2.7
0.106

16
0.63

6.3
0.248

13

-

1

1-LY6x-6/350

350

6
0.236

2.7
0.106

16
0.63

6.3
0.248

13

-

1, 3, 6

1-LY6x-10/350

350

10
0.394

5
0.197

23.5
0.925

9.3
0.366

21

-

1

 

Ordering number

Nominal (rated) resistance

Dimensions [mm/inch]

Vmax

Solder terminals

 

 

Preferred types

Measuring grid

Carrier

Ω

a

b

c

d

1-LY7x-0.6/120

120

0.6
0.024

1
0.039

2.3
0.091

5.6
0.22

1

LS7

1

1-LY7x-1.5/120

120

1.5
0.059

1.5
0.059

3.4
0.134

7.5
0.295

2.5

LS5

1

1-LY7x-3/120   

120

3
0.118

2.8
0.11

5.5
0.217

10.5
0.413

5

LS4

1

1-LY7x-6/120

120

6
0.236

6
0.236

9
0.354

15.5
0.61

10

LS4

-

1-LY7x-1.5/350

350

1.5
0.059

1.6
0.063

3.4
0.134

7.5
0.295

5

LS5

1, 3

1-LY7x-3/350

350

3
0.118

2.7
0.106

5.5
0.217

10.5
0.413

8.5

LS4

1

1-LY7x-6/350

350

6
0.236

5.6
0.22

9
0.354

15.5
0.61

18

LS4

-

 

Ordering number

Nominal (rated) resistance

Dimensions [mm/inch]

Vmax

Solder terminals

 

 

Preferred types

Measuring grid

Carrier

Ω

a

b

c

d

1-LY8x-0.6/120

120

0.6
0.024

1
0.039

5.6
0.22

2.3
0.091

1

LS7

-

1-LY8x-1.5/120

120

1.5
0.059

1.5
0.059

7.5
0.295

3.4
0.134

2.5

LS5

1

1-LY8x-3/120   

120

3
0.118

3
0.118

10.5
0.413

5.5
0.217

5

LS4

1

1-LY8x-6/120  

120

6
0.236

6
0.236

15.5
0.61

9
0.354

10

LS4

-

1-LY8x-1.5/350

350

1.5
0.059

1.5
0.059

7.5
0.295

3.4
0.134

5

LS5

1

1-LY8x-3/350

350

3
0.118

3
0.118

10.5
0.413

5.5
0.217

8.5

LS4

-

1-LY8x-6/350

350

6
0.236

5.6
0.22

15.5
0.61

9
0.354

18

LS4

1

 

Ordering number        

Nominal (rated) resistance

Dimensions [mm/inch]

Vmax

Preferred types

Measuring grid

Carrier

Ω

a

b

c

d

1-LY9x-1.5/350_E

350

1.5
0.059

2
0.078

4.7
0.185

6.6
0.259

5

1

1-LY9x-3/350_E

350

3
0.118

2
0.078

6.3
0.248

7
0.275

7.5

1

1-LY9x-6/350_E

350

6
0.236

3.8
0.149

9.5
0.374

9.5
0.374

15

1

The following temperature matching codes (1 … 9) apply to all types

1 = Ferritic steel (10.8 ppm/K; 6.0 ppm/°F)
3 = Aluminum (23 ppm/K; 12.8 ppm/°F)
5 = Austenitic steel (16 ppm/K, 8.9 ppm/°F)
6 = Silica/composite (0,5 ppm/K; 0.3 ppm/°F)
7 = Titanium and gray cast iron (9 ppm/K; 5.0 ppm/°F)
8 = Plastic (65 ppm/K; 36.1 ppm/°F)
9 = Molybdenum (5.4 ppm/K; 3.0 ppm/°F)

Remarks on Y Series

1) Strain gages are available in various temperature matches.
Insert the code in place of the placeholder “” to get the ordering number of the strain gage you need

2) Only available in matches for aluminum, ferritic and austenitic steel

3) Maximum permissible effective supply voltage (specified for steel)

4) Preferred types (available from stock) with the temperature matches specified in the column

5) With application aid (cut-to-size polyimide adhesive strip for easy positioning)

 

 

Linear (1 grid)

LY1

Standard strain gauge with leads

LY2

Leads on each side of the grid

LY4

Standard strain gauge with solder tabs

LY5

Narrow strain gauge with leads on each end of the grid

LY6

Solder tabs with integrated strain relief

LY7

Tabs on each side of the grid

LY8

Tabs on each end of the grid

 

 

LY9

Solder pads laterally

HBMshop See prices, availability and get an instant quote.
Get a quote now!

Ask your HBM Sales Engineer

Please send me


Continue

Ask your HBM Sales Engineer

Please send me


Continue

Individual offer