See All Software See All Instruments See All Transducers See All Vibration Testing Equipment See All Electroacoustics See All Acoustic End-of-Line Test Systems See All Academy See All Resource Center See All Applications See All Industries See All Services See All Support See All Our Business See All Our History See All Global Presence
arrow_back_ios

Main Menu

See All Analysis & Simulation Software See All DAQ Software See All Drivers & API See All Utility See All Vibration Control See All High Precision and Calibration Systems See All DAQ Systems See All S&V Hand-held Devices See All Industrial Electronics See All Power Analyzer See All S&V Signal Conditioner See All Acoustic Transducers See All Current and Voltage Sensors See All Displacement Sensors See All Force Sensors See All Load Cells See All Multi Component Sensors See All Pressure Sensors See All Strain Sensors See All Strain Gauges See All Temperature Sensors See All Tilt Sensors See All Torque Sensors See All Vibration See All Accessories for Vibration Testing Equipment See All Vibration Controllers See All Measurement Exciters See All Modal Exciters See All Power Amplifiers See All LDS Shaker Systems See All Test Solutions See All Actuators See All Combustion Engines See All Durability See All eDrive See All Production Testing Sensors See All Transmission & Gearboxes See All Turbo Charger See All Training Courses See All Acoustics See All Asset & Process Monitoring See All Custom Sensors See All Durability & Fatigue See All Electric Power Testing See All NVH See All Reliability See All Vibration See All Weighing See All Automotive & Ground Transportation See All Calibration See All Installation, Maintenance & Repair See All Support Brüel & Kjær See All Release Notes See All Compliance
arrow_back_ios

Main Menu

See All nCode - Durability and Fatigue Analysis See All ReliaSoft - Reliability Analysis and Management See All API See All Experimental Testing See All Electroacoustics See All Noise Source Identification See All Environmental Noise See All Sound Power and Sound Pressure See All Noise Certification See All Industrial Process Control See All Structural Health Monitoring See All Electrical Devices Testing See All Electrical Systems Testing See All Grid Testing See All High-Voltage Testing See All Vibration Testing with Electrodynamic Shakers See All Structural Dynamics See All Machine Analysis and Diagnostics See All Dynamic Weighing See All Vehicle Electrification See All Calibration Services for Transducers See All Calibration Services for Handheld Instruments See All Calibration Services for Instruments & DAQ See All On-Site Calibration See All Resources See All Software License Management

1. Introduction of a Modular Multi-Level Converter at the Osaka Institute of Technology

Offshore wind farming is a power generation method that make the best possible use of Japan's long coastline, and in recent years, initiatives are underway to harness wind power in a cost-effective manner (1). Power generated by an offshore wind farm must be transported to land efficiently and inexpensively. The use of a Solid State Transformer (SST) has been recommended, considering that smaller and lighter transformer equipment is necessary to keep costs low. Using a Modular Multi-Level Converter (MMC) could prove especially beneficial, since it is highly efficient, able to be mass produced at low cost, and is flexible enough to handle capacity increases (2). In this paper, we first describe the MMC being researched and developed at the Osaka Institute of Technology, and then show an example of its use in an experiment that was measured with the HBM/GEN series.

2. Offshore Wind Farm and SST

Power generated by an offshore wind farm must be transported to land, and it is well-known that costs for transporting power over long distances can be reduced by using DC power transmission instead of AC power transmission. Fig. 1 shows the DC power transmission system layout of a conventional offshore wind farm (2). The power generator output is boosted and isolated using a 50 or 60 Hz commercial transformer and is then converted to DC by the converter. This configuration poses a problem, because the inductors and capacitors inside the transformer and converter are heavy and have high capacities. One way to make transformers and inductors smaller is by increasing the frequency of the transformer. Doing this will allow the size of the magnetic material to be reduced. Setting the frequency to 10 kHz will enable approximately 1/10 capacity reduction (2). Fig. 2 is a schematic of a DC power transmission system employing a high frequency transformer (2). The conversion system that employs a high frequency transformer as in Fig. 2 is called a Solid State Transformer or SST. Once the SST has converted the generator output to direct current, it converts it to a high frequency alternating current. The AC current is then boosted and isolated by a high frequency transformer and then converted back to DC. The SST contains more transformers than a conventional commercial transformer.However, the capacity and weight of the entire SST can be made smaller. It does, however, perform a greater number of conversions, which means its efficiency is lower. Consequently, the efficiency of the converter needs to be improved.
null
null

3. Modular Multi-Level Converter Application

null
null
Using a low-loss switching device is one way to improve the efficiency of the converter. However, since offshore wind farms handle 250 kV to 500 kV in direct current, a high voltage class device like a thyristor must be used for the general converter. The drawback of the thyristor, though, is that it entails large losses. Another disadvantage is its slow switching speed, which makes it difficult to attain high frequencies. Utilizing an MMC is an effective way to overcome these issues. Fig. 3 is a circuit diagram of the MMC. The MMC is comprised of several modules. The switching device used in each module supports low voltages and can handle high voltages in multiple steps. By using the MMC, therefore, we can expect the SST to be highly efficient. Moreover, when the MMC has a high capacity, it is easily scalable by increasing the number of modules, and if the module is mass produced, its cost can be reduced. Fig.3 shows the circuit configuration used for AC/DC conversion. In addition, the MMC can perform bidirectional power conversions, so that it may be used as a DC/AC converter. Fig. 4 shows the circuit diagrams of the module. Adopting a half bridge circuit in the module enables the number of devices to be minimized. However, the module cannot output a negative voltage. Conversely, with a full bridge circuit MMC the number of devices can be increased, and negative voltages can be output by the module allowing it, in turn, to control voltages better than the half bridge circuit MMC, and to exert control over a wider range than the half bridge circuit MMC.

4. MMC Evaluation

Fig. 5 shows the MMC developed by the Osaka Institute of Technology. It is comprised of a total of 24 modules, 8 modules for each phase. Two module circuits are mounted on each module circuit board. It has a capacity of 10 kVA, and the PWM carrier frequency is 20 kHz or less. Fig. 6 shows the system configuration used during the experiment. 400 VDC is generated through a rectifier connected to a three-phase system. Then it is converted to three phase 200 V/400 Hz by a two-level inverter, after which it is isolated by a high frequency transformer, and then input to the MMC. The operation of the MMC is then evaluated, as it converts to 400 VDC. Furthermore, as the output of the MMC is input directly to the 2-level inverter, only the power loss of the converter is supplied from the three-phase system. Fig. 7 shows the setup for the experiment. To analyze the MMC operation, we had to monitor a total of 12 channels simultaneously, including the capacitor voltage of the module, and the currents and voltages of the switching devices. A typical oscilloscope does not have enough channels, so we used a high speed GEN7tA multichannel recorder. Also, the GEN7tA has a sampling of 2 MS/s, and so we were able to measure superharmonics. Moreover, we were able to measure the power of the MMC simultaneously by using the eDrive dynamic power analyze function. Fig. 8 shows an example of the measurement results of the capacitor voltages for each module. The result clearly shows that the capacitor voltages fluctuate due to MMC operation. The reference potentials of the capacitor voltages are different for each module. Therefore, if a typical oscilloscope is used, we would need a differential probe for each measurement point, whereas with the GEN7tA, the voltage input part is isolated (max. input voltage: ±1000 V), so that it is possible to measure the voltage at many points without the use of differential probes.
null
null
null
null

5. Summary

The MMC connects several modules in multiple steps. Therefore, to evaluate the MMC we had to measure many voltages and currents. The GEN7tA allowed measurement of up to 42 channels, and to make a detailed operational analysis of the MMC. In future experiments, the Osaka Institute of Technology plans to use the GEN7tA to measure efficiency and switching waveforms.

About OIT

Osaka Institute of Technology is a private technical university located in Osaka, Japan. It was founded in 1922 and aims to "Develop specialists with science-based practical skills who play an important role in society." OIT offers different undergraduate, graduate and post-graduate degrees in the fields of engineering, robotics and design, information science and technology, as well as intellectual property. Project-based practical learning, like this offshore wind farming system as an example for sustainable and efficient power generation, is what distinguishes Osaka Institute of Technology from other universities. 