See All Software See All Instruments See All Transducers See All Vibration Testing Equipment See All Electroacoustics See All Acoustic End-of-Line Test Systems See All Academy See All Resource Center See All Applications See All Industries See All Services See All Support See All Our Business See All Our History See All Global Presence
arrow_back_ios

Main Menu

See All Analysis & Simulation Software See All DAQ Software See All Drivers & API See All Utility See All Vibration Control See All High Precision and Calibration Systems See All DAQ Systems See All S&V Hand-held Devices See All Industrial Electronics See All Power Analyzer See All S&V Signal Conditioner See All Acoustic Transducers See All Current and Voltage Sensors See All Displacement Sensors See All Force Sensors See All Load Cells See All Multi Component Sensors See All Pressure Sensors See All Strain Sensors See All Strain Gauges See All Temperature Sensors See All Tilt Sensors See All Torque Sensors See All Vibration See All Accessories for Vibration Testing Equipment See All Vibration Controllers See All Measurement Exciters See All Modal Exciters See All Power Amplifiers See All LDS Shaker Systems See All Test Solutions See All Actuators See All Combustion Engines See All Durability See All eDrive See All Production Testing Sensors See All Transmission & Gearboxes See All Turbo Charger See All Training Courses See All Acoustics See All Asset & Process Monitoring See All Custom Sensors See All Durability & Fatigue See All Electric Power Testing See All NVH See All Reliability See All Vibration See All Weighing See All Automotive & Ground Transportation See All Calibration See All Installation, Maintenance & Repair See All Support Brüel & Kjær See All Release Notes See All Compliance
arrow_back_ios

Main Menu

See All nCode - Durability and Fatigue Analysis See All ReliaSoft - Reliability Analysis and Management See All API See All Experimental Testing See All Electroacoustics See All Noise Source Identification See All Environmental Noise See All Sound Power and Sound Pressure See All Noise Certification See All Industrial Process Control See All Structural Health Monitoring See All Electrical Devices Testing See All Electrical Systems Testing See All Grid Testing See All High-Voltage Testing See All Vibration Testing with Electrodynamic Shakers See All Structural Dynamics See All Machine Analysis and Diagnostics See All Dynamic Weighing See All Vehicle Electrification See All Calibration Services for Transducers See All Calibration Services for Handheld Instruments See All Calibration Services for Instruments & DAQ See All On-Site Calibration See All Resources See All Software License Management

MACLoC - The Intelligent Climbing Wall

MACLoC, ITALY

Introduction

MACLoC is the acronym for Multi-Axis Climbing Load Cells for performance analysis in sport climbing, a research team at Turin and Milan Polytechnic Universities. With the support of HBK, the team developed the prototype for a new type of “intelligent” climbing wall. Combining multi-axis force transducers and a Quantum X data acquisition system, the wall provides the climber with real-time information on his contact forces and the center of their mass.

chevron_left
chevron_right

Performance Analysis in Sports Climbing

MACLoC is the acronym for Multi-Axis Climbing Load Cells for performance analysis in sport climbing, a team of researchers and students from Turin and Milan Polytechnic Universities. MACLoC aimed to gather insights into the mechanics of climbing in order to provide athletes with detailed feedback on their training progress and the technique being used. Force measurement on the holds needed to be accurate regardless of the force application point.

Together with HBK, the project group developed the prototype for a new type of “intelligent” climbing wall, which has been registered with the European Patent Office. Combining multi-axis force transducers and a QuantumX data acquisition system, the wall provides climbers with real-time information on their contact forces and the center of their mass. These valuable insights into the mechanics of climbing allow rapid technical improvements in a highly complex and growing field of sports.

INTERNAL USE - Case Study  macloc Sensorized_wall

Sports Climbing - A Challenge for Body and Mind

Indoor climbing is a sport that is currently trending worldwide, and for good reason; like most sports, climbing combines stamina and strength, both physical and emotional. As it happens to be, beginners today find it very tiring to master the right grips and techniques. In order to grasp the handles on climbing walls properly and to shift weight correctly, the combined efforts of an experienced trainer and endless attempts are necessary.

But what if a wall itself would be able to give the athlete individual feedback on their learning path? This “intelligent climbing wall” is the brainchild of the MACLoC research team at the Alta Scuola Politecnico in Turin and Milan. Supported by HBK and RGTech, the team has developed a climbing wall with multi-axis force transducers that are capable of identifying the climber's contact forces and calculating the center of their mass in real time. For this purpose, the multi-axis sensors were fitted with HBK strain gauges and connected to a MX840B module of the QuantumX data acquisition system from HBK.

The Role of the Force Transducer

A force sensor on each single hold that can measure the forces along the three spatial components, normalized with respect to the climber’s weight, can be the technological bridge between sport technique and body power. Especially the knowledge of the four applied forces allows plotting the position of the body’s center of mass along the path to monitor the correct distribution of load. A climbing path with 10-12-14 smart holds can be used to analyze the efficiency and the correctness of the climber’s movements.

This synthesis can be carried out substantially in two different ways: comparing the data of an amateur and a professional athlete in order to highlight the significant technical differences, or monitoring the improvements of a single climber to show which gesture or body coordination caused this improvement. As a matter of fact, different climbers on a given path will usually show a different behavior.

"Apart from the excellent service provided during the testing and the evaluation phase of the project, the large and versatile product offering was another reason to work with HBK for this particular application. They enabled us to find a complete solution for our project. We opted for strain gauges and the MX840B module of QuantumX to develop the prototype of the sensorized climbing wall."

Quote from Professor Raffaella Sesana from the Department of Mechanical and Aerospace at Turin Polytechnic University. The partnership between HBK and the engineering team at Alta Scuola Politecnica has been lasting for more than three decades so far.

INTERNAL USE - Case Study  macloc HoldSensor

View of the multi-axis force transducer within the wall hold

INTERNAL USE - Case Study  macloc TheTeam

The MACLoC research team

INTERNAL USE - Case Study  macloc QuantumX_2

The measurement chain

The Learning Curve

When professional athletes are observed, they tend to give the impression that they are not at all struggling to complete a climbing route. It can be expected that a more experienced climber will use less force in relation to his body mass compared to a beginner, and the former’s higher performance will not solely be a result of greater athletic capacity. Apart from a comparison between athletes, it should be noted that the same climber repeating a certain route several times will also evolve himself in the applied force on the wall, even after just a few hours of training. This fact is surely not due to a miraculous immediate strength improvement, but rather due to better coordination and posture. While measuring the evolution of such performances, it can be expected that the force on the axes decreases with the number of repetitions up to a certain asymptote, such as charging a capacitor. While practicing, this can be seen as the learning curve of the climber on a specific route.

The Advantages of the Prototype

These two analysis modes combined can lead to many other interesting analyses: comparing the learning curve of different climbers, as well as knowing how experienced climbers execute the route and apply forces on climbing holds, could help trainers and trainees with the development of specific training programs to get better results in a shorter period of time. Despite the numerous advantages listed above, little has been done so far in this direction, mostly due to the cost of instrumenting a wall for the same purpose and also due to a certain “suspicious adversity” towards technology among conservative climbers. Following the successful development of the prototype, the model has been registered for patent.
INTERNAL USE - Case Study  macloc QuantumX

With the help of HBM, MACLoC was able to develop an innovative climbing wall and data analysis system for faster and easier acquisition of professional and individual climbing techniques.

About MACLoC

MACLoC (Multi-Axis Climbing Load Cells) was a project at Alta Scuola Politecnica in the framework of the 12th edition of A&T- Automation and Testing Trade Fair in Turin, Italy. Led by professors Raffaella Sesana and Daniela Maffiodo (both DIMEAS, Turin Polytechnic University) as well as Alessandro Colombo (DEIB, Milan Polytechnic University), a group of 8 students developed a technology-based approach to climbing. The sport was chosen due to its growing popularity as well as its complexity. Measurement of the contact forces and calculation of the centre of mass helps with the understanding of the mechanics of climbing, thus allows a faster optimization of technique and training sessions.

Professor Raffaella Sesana

Technology used

Other case studies

Showing 9 of 511 items