CLIP—Analog Amplifier for Industrial Applications

Simply ‘clip on’ and get started! The CLIP analog amplifier comes in a lightweight plastic housing. It is designed for applications in production or test benches, and can be easily installed on DIN rails. CLIP modules have DC or CF supply and can be connected to all strain gauge transducers for measuring force, displacement or torque as well as load cells. Moreover, many modules are available for expansion and individual adaptation to respective applications. CLIP combines quick integration and ease of use, and is a cost-effective solution for reliably acquiring physical quantities in harsh industrial environments.

  • HBM accuracy class: 0.1
  • Measuring inputs for many common signals in production and test benches
  • Optional expansion with: current output, limit switch, tare module

Flexible and precise

  • 0.1 accuracy class
  • For all strain gauge transducers in full bridge configuration such as force, displacement, and torque transducers as well as load cells
  • Robust and reliable 600 Hz carrier-frequency amplifier version for weighing technology applications
  • Fast DC amplifier version with high measurement bandwidth for applications in factory automation
  • Add-on modules for peak and limit values as well as tare function for control tasks

Adaptability to many applications, due to different transducer types and modules that can be combined

Quickly integrable, easy to use

  • All CLIP amplifiers have a ±10 V analog output
  • A ±20 mA, 4-20 mA current output is available as an option
  • DIP switches and adjustment potentiometers on the front allow convenient adjustment
  • Measurement range can be adjusted without a pre-defined load, using an internal calibration signal
  • Operation and parameterization via front control elements

Reliable measurement results, due to amplifiers that provide outstanding long-term stability and low noise

Robust

  • High EMC and safe operation, even in harsh industrial environments
  • Zener barriers (SD01A) allow use in areas with potentially explosive atmospheres
  • Standardized, tried and tested installation on DIN rails according to DIN 50022 in the control cabinet

Installation in a few simple steps—no software required

CLIP modules at a glance

AE101

DC amplifier for strain gauge full bridges; for static and dynamic measurements (<6kHz); selectable excitation voltage; 0.1 ... 8mV/V measuring range

AE301:

CF amplifier (600Hz) for strain gauge full bridges; very high zero point stability; up to 4 strain gauge transducers can be operated in parallel; 0.03% typ. linearity error; 0.2 ... 8mV/V measuring range

AE501:

CF amplifier (4.8 kHz) for inductive half and full bridges; 8 ... 400mV/V measuring range

GR201:

Dual limit switches with 2 separate inputs; reference voltage adjustable between ?0V and +10V; switching direction, hysteresis and switching time can be selected

TS101:

Automatic tare and store unit; acquisition of peak values and instantaneous values; envelope curve function selectable

EM201, EM201K2:

Single and/or dual find stage for +20mA or +4 ...+20mA current output; permissible load resistance <500 Ohm

NT101A, NT102A:

Power supply for modules (230V, 115V/50 ... 60Hz); up to 4 modules can be connected (15V= / max. 650mA); with overload protection

The complete flexibility of the system combined with the ease of use, results in the ultimate solution in measurement and control. And if you require a suitable system for operation in an aggressive industrial environment - we can provide - as clipIG system - an inexpensive system, using standard modules mounted in a robust housing sealed to IP65. We can also supply many other configurations on request. Do you have an application? We are ready to help you.

Clip modules

AE101: DC amplifier for strain gauge full bridges; for static and dynamic measurements (<6kHz); selectable excitation voltage; 0.1 ... 8mV/V measuring range

AE301: CF amplifier (600Hz) for strain gauge full bridges; very high zero point stability; up to 4 strain gauge transducers can be operated in parallel; 0.03% typ. linearity error; 0.2 ... 8mV/V measuring range

AE501: CF amplifier (4.8 kHz) for inductive half and full bridges; 8 ... 400mV/V measuring range

GR201: Dual limit switches with 2 separate inputs; reference voltage adjustable between ?0V and +10V; switching direction, hysteresis and switching time can be selected

TS101: Automatic tare and store unit; acquisition of peak values and instantaneous values; envelope curve function selectable

EM201, EM201K2: Single and/or dual find stage for +20mA or +4 ...+20mA current output; permissible load resistance <500 Ohm

NT101A, NT102A: Power supply for modules (230V, 115V/50 ... 60Hz); up to 4 modules can be connected (15V= / max. 650mA); with overload protection