Amplifier Modules (ML) for MGCplus

Single-channel

ML01B DC amplifier for voltages, currents, thermocouples and current-fed piezoelectric transducers

  • TEDS Transducer identification
  • Accuracy class: 0.03
  • Automatic tare
  • 2 peak-value memories
  • 4 limit switches
  • Low-pass filter
  • Calibration signal
  • Transducer connection in 6-wire circuit
  • Width: 4 divs

ML10B DC amplifier for strain gauges (full, half and quarter bridges), piezoresitive and current-fed piezoelectric transducers and torque transducers

  • TEDS Transducer identification
  • Accuracy class: 0.03
  • Automatic tare
  • 2 peak-value memories
  • 4 limit switches
  • Low-pass filter
  • Calibration signal
  • Transducer connection in 6-wire circuit
  • Width: 4 divs

ML30B Carrier-frequency amplifier for strain gauge transducers in full bridge circuit 600 Hz carrier frequency

  • TEDS Transducer identification
  • Accuracy class: 0.03
  • Automatic tare
  • 2 peak-value memories
  • 4 limit switches
  • Low-pass filter
  • Calibration signal
  • Transducer connection in 6-wire circuit
  • Width: 4 divs

ML35B: Carrier-frequency amplifier for resistance thermometers Pt100 and Pt10

  • 75 Hz carrier frequency
  • TEDS Transducer identification
  • Accuracy class: 0.03
  • Automatic tare
  • 2 peak-value memories
  • 4 limit switches
  • Low-pass filter
  • Calibration signal
  • Width: 4 divs

ML38B: Precision carrier-frequency amplifier for strain gauge transducers in full bridge circuit

  • 225 Hz carrier frequency
  • TEDS Transducer identification
  • Accuracy class: 0.0025
  • Automatic tare
  • 2 peak-value memories
  • 4 limit switches
  • Low-pass filter
  • Calibration signal
  • Polynomial characteristics
  • Transducer connection in 6-wire circuit
  • For use with type AP01i and AP03i connection boards
  • Width: 8 divs

ML55B Carrier-frequency amplifier for strain gauge and inductive transducers in half and full bridge circuit and torque transducers

  • 4.8 kHz carrier frequency
  • TEDS Transducer identification
  • Accuracy class: 0.03
  • Automatic tare
  • 2 peak-value memories
  • 4 limit switches
  • Low-pass filter
  • Calibration signal
  • Transducer connection in 6-wire circuit
  • Width: 4 divs

ML55BS6 Carrier-frequency amplifier for strain gauge and inductive transducers in half and full bridge circuit and torque transducers

  • 9.6 kHz carrier frequency (0 - 3 kHz measurement frequency range)
  • TEDS Transducer identification
  • Accuracy class: 0.03
  • Automatic tare
  • 2 peak-value memories
  • 4 limit switches
  • Low-pass filter
  • Calibration signal
  • Transducer connection in 6-wire circuit
  • Width: 4 divs

ML60B Amplifier for incremental encoders, frequency signals and torque transducers with frequency output (T10F, T30FN, T32FN, T34FN)

  • TEDS Transducer identification
  • Accuracy class: 0.01
  • Automatic tare
  • 2 peak-value memories
  • 4 limit switches
  • Low-pass filter
  • Calibration signal
  • Width: 4 divs

Multi-channel

ML455 4 channel carrier-frequency amplifier for strain gauge and inductive transducers in half and full bridge circuit and LVDT

  • 4.8 kHz carrier frequency
  • TEDS Transducer identification
  • Accuracy class: 0.05
  • Automatic tare
  • 2 peak-value memories per channel
  • Low-pass filter
  • Calibration signal
  • Transducer settings individually definable for each subchannel
  • Usable with connection board type AP455i and AP455iS6
  • Width: 4 divs

ML460 4-channel frequency counter for frequency counting (up to 500 kHz), pulse counting, pulse duration measurement and pulse width demodulation

  • TEDS Transducer identification
  • Accuracy class: 0.01
  • 2 peak-value memories per channel
  • Low-pass filter
  • Usable with connection board type AP460i
  • Width: 4 divs

ML801B Multi-channel amplifier with 8 channels for acquisition of physical quantities like voltages, temperature and strain (quarter, half, full, bridge)

  • TEDS Transducer identification
  • Accuracy class: ≥ 0.05
  • Automatic tare
  • 2 peak-value memories per channel
  • Low-pass filter
  • Calibration signal
  • Width: 4 divs  

Special-function

ML70B Programmable module

  • Usable only in systems with CP22, CP32 and CP42 or in systems without communication processor
  • Width: 4 divs

ML71B Communication interface to receive CAN-bus data

  • Usable with connection board type AP71
  • Usable only in systems with CP22, CP32 and CP42 or in systems without communication processor
  • Width: 4 divs

ML71BS6 Communication interface to send CAN-bus data

  • Usable with connection board type AP71
  • Usable only in systems with CP22, CP32 and CP42 or in systems without communication processor
  • Width: 4 divs

ML74B Special function module to connect CANHEAD® measurement chains

  • Usable with connection board type AP74
  • Usable only in systems with CP22, CP32 and CP42 or in systems without communication processor
  • Width: 4 divs

ML77B PROFIBUS DP communication module (MGCplus with ML77B + AP77 is a PROFIBUS DP slave)

  • Usable with connection board type AP77
  • Usable only in systems with CP22, CP32 and CP42 or in systems without communication processor
  • Width: 4 divs

ML78B Multi-channel I/O module

  • Usable with connection board type AP75 (8 digital inputs and 8 digital outputs (24V)) and/or AP78 (10 analog outputs, 8 thereof electrically isolated (±10 V))
  • Usable only in systems with CP22, CP32 and CP42 or in systems without communication processor