Pre-wired Strain Gauges: Fast, Safe and Convenient to Use

Leave the soldering to HBM and avoid a potential source of error by ordering pre-wired strain gauges. HBM has set up a “fast lane” service for small orders, which helps provide you the strain gauge you need with the cable of required length within only 4 days.

HBM strain gauges comply with current RoHS requirements, and new materials have been used in making the stranded connection wires more flexible and easier to use. The temperature range has also been expanded to 150°C.

Advantages

  • Fast installation
  • Increased reliability
  • Fluoropolymer-insulated stranded wire (with non-stick properties)
  • Temperature compensation for most materials
  • Cable length from 0.5 m to 10 m (RJ11 connectors upon request)
  • Grid length from 0.6 mm to 10 mm  
  • Gauges with 3- and 4-wire configurations
     

Configure your pre-wired gauge

Pre-wired strain gauges are available for the following materials:

  Materialx (ordering number)    
Ferritic steel (11.8 ppm/K)1
Aluminum (23 ppm/K) 3
Austenitic steel (16 ppm/K)5
Silica/composite (0.5 ppm/K)6
Titanium (9 ppm/K)7
Plastic (65 ppm/K)8
Molybdenum (5.4 ppm/K)9


#These strain gauges are only available with temperature response matching to ferritic steel, austenitic steel and aluminum.

Configurable pre-wired strain gauges

 

Ordering number:
K-CLY4x

Nominal (rated) resistance

Dimensions [mm/inch]

Solder terminals are not required

Preferred types

Measuring grid

Carrier

[Ω]

a

b

c

d

 

K-CLY4x-0.6/120#

120

0.6
0.024

1.1
0.043

6
0.236

4
0.157

 -

K-CLY4x-1.5/120

120

1.5
0.059

1.2
0.047

7
0.276

4
0.157

 -
K-CLY4x-3/120

120

3
0.118

1.2
0.047

8
0.315

5
0.197

 1
K-CLY4x-6/120

120

6
0.236

2.7
0.106

13.9
0.547

5.9
0.232

 1,3
K-CLY4x-10/12012010
0.394
4.9
0.193
18
0.709
8
0.315
 1
K-CLY4x-20/12012020
0.787
0.5
0.02
31.8
1.252
8.2
0.323
 1
K-CLY4x-50/12012050
1.969
0.8
0.031
63.6
2.504
8.2
0.323
 1
K-CLY4x-100/120120

100
3.937

1
0.039

114.8
4.52

8.2
0.323

 -
K-CLY4x-150/120120150
5.906
1.2
0.047
165.6
6.52
8.2
0.323
 -
K-CLY4x-1.5/350#3501.5
0.059
2.3
0.091
9.2
0.362
5.9
0.232
 -
K-CLY4x-3/3503503
0.118
2.5
0.098
10.9
0.429
5.9
0.232
 -
K-CLY4x-6/3503506
0.236
2.8
0.11
13.9
0.547
5.9
0.232
 1
K-CLY4x-10/35035010
0.394
5
0.197
18
0.709
8
0.315
 -
K-CLY4x-3/7007003
0.118
2.7
0.106
10.9
0.429
5.9
0.232
 -
K-CLY4x-6/7007006
0.236
4.1
0.161
13.9
0.547
5.9
0.232
 -
K-CLY4x-10/70070010
0.394
5
0.197
18
0.709
8
0.315
 -
K-CLY4x-3/1000#10003
0.118
2.7
0.106
10.9
0.429
5.9
0.232
 -
K-CLY4x-6/100010006
0.236
4.2
0.165
13.9
0.547
5.9
0.232
 -
K-CLY4x-10/1000100010
0.394
5
0.197
18
0.709
8
0.315
 -

 

Ordering number:
K-CLY9x

Nominal (rated) resistance

Dimensions [mm/inch]

Solder terminals are not required

Preferred types

Measuring grid

Carrier

[Ω]

a      

b

c

d

 

K-CLY9x-1.5/120_E

120

1,5

2

6,6 

  

K-CLY9x-3/120_E

120

 3

 2

 7

 6,3

 1
K-CLY9x-6/120_E

120

 6

 4

 9,5

 9,5

 -

K-CLY9x-1.5/350_E

350

 1,5

 2

 6,6

 4,7

 -
K-CLY9x-3/350_E350

 3

 2

 7

 6,3

 1
K-CLY9x-6/350_E350

 6

 3,8

 9,5

 9,5

 -

 


 

Ordering number:
K-CXY3x

Nominal (rated) resistance

Dimensions [mm/inch]

Solder terminals are not required

Preferred types

Measuring grid

Carrier

[Ω]

a

b

c

d

 

K-CXY3x-0.6/120#

120

0.6
0.024

1
0.039

7
0.276
6
0.236
 -

K-CXY3x-1.5/120

120

1.5
0.059

1.6
0.063
8
0.315
6.3
0.248
 -
K-CXY3x-3/120

120

3
0.118

3.2
0.126

10.5
0.413
8
0.315
 -
K-CXY3x-6/120

120

6
0.236

6.3
0.248
17.5
0.689
12
0.472
 1
K-CXY3x-1.5/350#3501.5
0.059
1.7
0.067
7.7
0.303
6.3
0.248
 -
K-CXY3x-3/3503503
0.118
3.3
0.13
10.9
0.429
7.6
0.299
 1
K-CXY3x-6/3503506
0.236
6.5
0.256
18
0.709
12
0.472
 3

 


 

Ordering number:
K-CXY4x

Nominal (rated) resistance

Dimensions [mm/inch]

Solder terminals are not required

Preferred types

Measuring grid

Carrier

[Ω]

a

b1

b2

c

d

 

K-CXY4x-3/120

120

3
0.118

3
0.118

5.4
0.213

11
0.433

8
0.315

 -

K-CXY4x-6/120

120

6
0.236

6
0.236

10.2
0.402

16
0.63

12.2
0.48

 -
K-CXY4x-3/350

350

3
0.118

4.2
0.165

5.6
0.221

11
0.433

8
0.315

 -
K-CXY4x-6/350

350

6
0.236

6
0.236

10
0.394

16
0.63

12.2
0.48

 -
K-CXY4x-3/7007003
0.118
4.2
0.165
5.6
0.221
11
0.433
8
0.315
 -
K-CXY4x-6/7007006
0.236
6.1
0.24
9.9
0.39
16
0.63
12.2
0.48
 -

 


 

Ordering number:
K-CDY4x

Nominal (rated) resistance

Dimensions [mm/inch]

Solder terminals are not required

Preferred types

Measuring grid

Carrier

[Ω]

a

b

c

d

 

K-CDY4x-3/120

120

3
0.118

2.7
0.106

8.2
0.323

8
0.315

 -
 K-CDY4x-6/120

120

6
0.236

3.2
0.126

10.7
0.421

9
0.354

 -
 K-CDY4x-3/3503503
0.118
2.7
0.106
8.2
0.323
8
0.315
 -
 K-CDY4x-6/3503506
0.236
3.2
0.126
10.7
0.421
9
0.354
 1

 


 

Ordering number:
K-CRY8x

Nominal (rated) resistance

Dimensions [mm/inch]

Solder terminals are not required

Preferred types

Measuring grid

Carrier

[Ω]

a

b

c

d

 

K-CRY8x-0.6/120#

120

0.6
0.024

1.2
0.047

4.8
0.189

8.7
0.343

 -

K-CRY8x-1.5/120

120

1.5
0.059

1.3
0.051

8.2
0.323

14.6
0.575

 -
K-CRY8x-3/120

120

3
0.118

1.1
0.043

9.7
0.382

14.6
0.575

 1
K-CRY8x-6/120

120

6
0.236

3
0.118

13
0.512

22.9
0.902

 1,3
K-CRY8x-1.5/350#3501.5
0.059
1.6
0.063
8.2
0.323
14.6
0.575
 -
K-CRY8x-3/3503503
0.118
1.2
0.047
9.7
0.382
14.6
0.575
 -
K-CRY8x-6/3503506
0.236
2.8
0.11
13.1
0.516
22.9
0.902
 -

 

 

Ordering number:
K-CRY6x

Nominal (rated) resistance

Dimensions [mm/inch]

Solder terminals are not required

Preferred types

Measuring grid

Carrier

[Ω]

a

b

c

d

 

K-CRY6x-1.5/120K#

120

1.5
0.059

0.8
0.031

7.2
0.283

10.2
0.402

 -

K-CRY6x-1.5/120R#

120

1.5
0.059

0.8
0.031

8
0.315

13.5
0.531

 -

 

Standardized pre-wired strain gauges

Order selected strain gauges as standardized pre-wired models directly from stock and benefit from short delivery times. The gauges come with 50 mm preattached fluoropolymer-insulated wires, further options with 3 m connection cable will follow.

All standardized pre-wired strain gauges are available with temperature response matching to ferritic steel.


 

Ordering number:

Nominal (rated) resistance

Dimensions [mm/inch]

Solder terminals are not required

Measuring grid

Carrier

[Ω]

a

b

c

d

 

1-CLY41-3/120ZE

120

3
0.118
2.5
0.098
10.9
0.429
5.9
0.232
 
 1-CLY41-3/350ZE

350

3
0.118
2.5
0.098
10.9
0.429
5.9
0.232
 
 1-CLY41-6/120ZE1206
0.236
2.8
0.110
13.9
0.547
5.9
0.232
 
 1-CLY41-6/350ZE3506
0.236
2.7
0.106
13.9
0.547
5.9
0.232
 
     
 

Ordering number

Nominal (rated) resistance

Dimensions [mm/inch]

Solder terminals are not required

Measuring grid

Carrier

Ω

a

b

c

d

 

1-CLY91-3/350ZE

350

3
0.118
2
0.079
7
0.276
6.3
0.248
 

                                                                                                                                                                                                                                                                                                                                                                                                                           

     
           
        

Ordering number

            

Nominal (rated) resistance       

            

Dimensions [mm/inch]        

Solder terminals are not required

Measuring grid  

Carrier 

    

Ω

 

a  

 

b

         

c       

            

d     

             

1-CDY41-6/350ZE

            

350 

6
0.236
3.2
0.126
10.7
0.429
9
0.354
 
     
 

Ordering number

Nominal (rated) resistance

Dimensions [mm/inch]

Solder terminals are not required

Measuring grid

Carrier

Ω

a

b

c

d

 

1-CXY31-3/350ZE

350

3
0.118
3.3
0.165
10.9
0.429
7.6
0.299
 
     
 

Ordering number

Nominal (rated) resistance

Dimensions [mm/inch]

Solder terminals are not required

Measuring grid

Carrier

Ω

a

b1

b2

c

d

 

1-CXY41-3/350ZE

350

3
0.118
4.2
0.165
5.6
0.220
11
0.433
8
0.315
 
     
 

Ordering number

Nominal (rated) resistance

Dimensions [mm/inch]

Solder terminals are not required

Measuring grid

Carrier

Ω

a

b

c

d

 

1-CRY81-3/350ZE

350

3
0.118

1.2
0.047
9.7
0.382
14.6
0.575
 

Video: Learn how to bond a pre-wired strain gauge

 

Product Literature

Titel / BeskrivningSpråk
Data Sheets
German
English
Russian
Declaration of Conformity
German, English

Related Products

LY - linear
Linear strain gauges with 1 measurement grid is the first choice for strain measurements in only one direction. With types LY1, LY2, LY4, LY5, LY6...
XY T rosette
HBM XY strain gauges of the T rosettes type have 2 measuring grids arranged at a 90° degree offset from each other.
XY2 / XY4 - torsion
Types XY2 and XY4 are V-shaped strain gauges (SGs) with 2 measuring grids arranged at an angle of about 45° to the SG axis.
HBMshop Se priser, tillgänglighet och skriv ut prisinformation.
Begär en offert!

Fråga din försäljningsingenjör

Skicka mig:


Starta din förfrågan

Fråga din försäljningsingenjör

Skicka mig:


Starta din förfrågan

Individuellt erbjudande

Teknisk rådgivning