PACEline CMD Digital Charge Amplifier: Measures Signals From 50 pC to 2 Million pC

The PACEline CMD digital charge amplifier for piezoelectric sensors precisely measures fast force, torque and pressure signals. It is ideally suited to highly dynamic applications such as production monitoring in press processes or end-of-line testing in the automotive sector due to its very wide measurement range and fast data acquisition up to 50 kHz. PACEline CMD can be easily integrated via digital or analog interface and parameterized via Ethernet as well as Software and Adjustment Assistant. 

  • HBM accuracy class: 0.5
  • Measurement ranges: between 50 pC and 2 million pC
  • Degrees of protection: up to IP 65

Wide measuring range

  • Very wide measurement range and high dynamics
  • Measurement range freely adjustable or via SensorTeach
  • Calibration certificate included in scope of supply
  • Guaranteed accuracy also in partial ranges

Can be used in many applications due to extremely wide, individually adjustable measurement range.

Easy to use

  • Direct data transfer via Ethernet interface or 10 V analog output
  • Digital and analog signal inputs and outputs, peak value detection
  • Integrated Assistant for time-saving sensor adjustment
  • 2 parameterizations enable formulations to be quickly changed
  • Parameterization software including chart recorder and data storage

Easy to program and use due to digital interfaces and software support.

Highly reliable

  • High signal quality with 14 bit resolution
  • Robust design featuring IP 60 and IP 65 degree of protection
  • Selectable high-pass filter minimize signal drift
  • Electrically isolated signal inputs and outputs prevent faultsFast data acquisition up to 50 kHz measurement frequency

High-quality measurement result due to robust design and high EMC interference protection

PACEline CMD Videos

 
 

Available in 2 different versions

  • CMD600: For measuring ranges up to 600,000 pC
  • CMD2000: For measuring ranges up to 2,000,000 pC
  • Also available: ePlan macro, LabVIEW driver, API for programmers, software example projects, programming examples in Simatic Step7

    PACEline Accessories

Product Literature

題目/描述語言
參數表
Japanese
Japanese
Italian
English
German
English
German
French
French
操作手冊
Italian
English, German, French, Italian
English
French, German, English
附件
English
French
German
Italian
安全指南
French, German, English
Declaration of Conformity
多語言
多語言
固件

Archive including all current firmware for all modules of the CMD series (CMD600 and CMD2000).
Please use "CMD Firmware Updater for Version 3.62 and higher" on this page.

Date: 03/2016  |  Version: 3.74  |  Size: 248 KB
Related Documents:

多語言
軟體

This project is a macro-project and contains CAE data for Eplan Electric P8.

Date: 10/2011  |  Version: 1.00  |  Size: 18 MB

多語言

CMD Assistant and Firmware Loader for Windows 2000, XP, Vista, 7/8/10. Allows the easy setup of CMD modules, visualization and process-data storage. All required drivers are included and will be installed during startup.

Starting with assistant-version 1.2.4.0 only CMD with firmware 3.0 and higher can be used. Devices with firmware 2.9 and lower are shown in the device-scan but marked red with a note for firmware-update. Please do also a firmware-update for those devices, for features see release-notes.

Date: 03/2016  |  Version: 1.3.0.2  |  Size: 66 MB
Related Documents:

多語言

To simplify the use of CMD meauring amplifier a complete support for communication in form of a Labview driver is available, respectively Labview programs/subroutines called virtual instruments (VIs).
The purpose of this document is to explain in detail all aspects of the Labview CMD driver:

  • Driver structure
  • VI blocks
  • Application example – getting started

The CMD driver is completely written in Labview Professional Development System. In order to use the drivers the user will need Labview version 9.0.1 or later.
This example does not imply any warranty or guarantee.

Date: 07/2015  |  Size: 3 MB

多語言

This Siemens Step7 example describes a project to connect the type CMD measuring amplifier from HBM GmbH to a Siemens S7-315-2 PN/DP CPU via UDP and store the measured values transmitted via UDP in a data module. The measured values are to be read and processed with up to 1000 Hz via UDP.

HBM does not guarantee the completeness and correctness of this example.

Date: 08/2011  |  Size: 3 MB

多語言
Tech Notes

This is an instruction for adjusting a sensor with a CMD charge amplifier. The adjustment assistant is especially useful if a sensor is not calibrated, or assembled in a construction, for example as force bypass.

German

This is an instruction for adjusting a sensor with a CMD charge amplifier. The adjustment assistant is especially useful if a sensor is not calibrated, or assembled in a construction, for example as force bypass.

English

Related Products and Content

Tech note: How to use the CMD adjustment assistant
Learn how to adjust a sensor with the adjustment assistant of the CMD charge amplifier.
PACEline CLP Force Sensor [3kN ... 62kN]
Piezoelectric force washers for force measurement where space is a constraint
PACEline CMA
PACEline CMA 電荷放大器 (模擬放大器) 可以進行可靠的資料傳輸. 這可以通過信號調理到 +/-10 V 模擬標準放大器.
HBMshop 查看價格、庫存並獲得報價
馬上獲取報價!

向HBM銷售工程師詢問

請發給我:


開始詢價

向HBM銷售工程師詢問

請發給我:


開始詢價

單獨出價

技術諮詢

快速回應