What this means for you:

  • The installation of the strain gauges is significantly easier
  • The reliability of measurements is increased
  • Service life is extended through reduced stress

HBM is ahead of the times ensuring that its pre-wired strain gauges comply with RoHS requirements already today. No lead solder is used so that long term use in a wide range of applications is possible.

Cable lengths ranging from 0.5 m to 10 m are available with RJ11 connectors on request.

Special requirements

Do you have special requirements that are not met by any strain gauge from our standard range of products? Are you looking for a strain gauge that is equivalent to the product you currently use? Have you designed your own strain gauge?

Contact us and we will produce customized strain gauges according to your requirements, from quantities of 20 packages and up.

 

Ordering number

Nominal (rated) resistance

Dimensions [mm/inch]

Vmax 

Solder terminals are not required

Preferred types

Measuring grid

Carrier

Ω

a

b

c

d

 

K-LY4x-0.6/120#

120

0.6
0.024

1.1
0.043

6
0.236
4
0.157
1.5   -

K-LY4x-1.5/120

120

1.5
0.059

1.2
0.047
7
0.276
4
0.157
2.5   -
K-LY4x-3/120

120

3
0.118

1.2
0.047
8
0.315
5
0.197
4   1
K-LY4x-6/120

120

6
0.236

2.7
0.106
13.9
0.547
5.9
0.232
8   1,3
K-LY4x-10/120 120 10
0.394
4.9
0.193
18
0.709
8
0.315
14   1
K-LY4x-20/120 120 20
0.787
0.5
0.02
31.8
1.252
8.2
0.323
7   1
K-LY4x-50/120 120 50
1.969
0.8
0.031
63.6
2.504
8.2
0.323
12   1
K-LY4x-100/120 120 100
3.937
1
0.039
114.8
4.52

8.2
0.323

19   -
K-LY4x-150/120 120 150
5.906
1.2
0.047
165.6
6.52
8.2
0.323
5   -
K-LY4x-1.5/350# 350 1.5
0.059
2.3
0.091
9.2
0.362
5.9
0.232
6.5   -
K-LY4x-3/350 350 3
0.118
2.5
0.098
10.9
0.429
5.9
0.232
9   -
K-LY4x-6/350 350 6
0.236
2.8
0.11
13.9
0.547
5.9
0.232
15   1
K-LY4x-10/350 350 10
0.394
5
0.197
18
0.709
8
0.315
24   -
K-LY4x-3/700 700 3
0.118
2.7
0.106
10.9
0.429
5.9
0.232
13   -
K-LY4x-6/700 700 6
0.236
4.1
0.161
13.9
0.547
5.9
0.232
23   -
K-LY4x-10/700 700 10
0.394
5
0.197
18
0.709
8
0.315
33   -
K-LY4x-3/1000 1000 3
0.118
2.7
0.106
10.9
0.429
5.9
0.232
16   -
K-LY4x-6/1000 1000 6
0.236
4.2
0.165
13.9
0.547
5.9
0.232
27   -
K-LY4x-10/1000 1000 10
0.394
5
0.197
18
0.709
8
0.315
40   -

 

Ordering number

Nominal (rated) resistance

Dimensions [mm/inch]

Vmax 

Solder terminals are not required

Preferred types

Measuring grid

Carrier

Ω

a

b

c

d

 

K-XY3x-0.6/120#

120

0.6
0.024

1
0.039

7
0.276
6
0.236
1.5   -

K-XY3x-1.5/120

120

1.5
0.059

1.6
0.063
8
0.315
6.3
0.248
3   -
K-XY3x-3/120

120

3
0.118

3.2
0.126

10.5
0.413
8
0.315
5.5   -
K-XY3x-6/120

120

6
0.236

6.3
0.248
17.5
0.689
12
0.472
11   1
K-XY3x-1.5/350# 350 1.5
0.059
1.7
0.067
7.7
0.303
6.3
0.248
5   -
K-XY3x-3/350 350 3
0.118
3.3
0.13
10.9
0.429
7.6
0.299
10   1
K-XY3x-6/350 350 6
0.236
6.5
0.256
18
0.709
12
0.472
20   3

 

 


 

Ordering number

Nominal (rated) resistance

Dimensions [mm/inch]

Vmax 

Solder terminals are not required

Preferred types

Measuring grid

Carrier

Ω

a

b1

b2

c

d

 

K-XY4x-3/120

120

3
0.118

3
0.118

5.4
0.213

11
0.433
8
0.315
5   -

K-XY4x-6/120

120

6
0.236

6
0.236
10.2
0.402
16
0.63
12.2
0.48
9.5   -
K-XY4x-3/350

350

3
0.118

4.2
0.165

5.6
0.221

11
0.433

8
0.315
9.5   -
K-XY4x-6/350

350

6
0.236

6
0.236
10
0.394
16
0.63
12.2
0.48
16   -
K-XY4x-3/700 700 3
0.118
4.2
0.165
5.6
0.221
11
0.433
8
0.315
13.5   -
K-XY4x-6/700 700 6
0.236
6.1
0.24
9.9
0.39
16
0.63
12.2
0.48
23   -

 

Ordering number

Nominal (rated) resistance

Dimensions [mm/inch]

Vmax 

Solder terminals are not required

Preferred types

Measuring grid

Carrier

Ω

a

b

c

d

 

K-DY4x-3/120

120

3
0.118

2.7
0.106

8.2
0.323
8
0.315
8.5   -
  K-DY4x-6/120

120

6
0.236

3.2
0.126

10.7
0.421
9
0.354
13   -
  K-DY4x-3/350 350 3
0.118
2.7
0.106
8.2
0.323
8
0.315
8.5   -
  K-DY4x-6/350 350 6
0.236
3.2
0.126
10.7
0.421
9
0.354
13   1

 

Ordering number

Nominal (rated) resistance

Dimensions [mm/inch]

Vmax 

Solder terminals are not required

Preferred types

Measuring grid

Carrier

Ω

a

b

c

d

 

K-RY8x-0.6/120#

120

0.6
0.024

1.2
0.047

4.8
0.189
8.7
0.343
1.6   -

K-RY8x-1.5/120

120

1.5
0.059

1.3
0.051
8.2
0.323
14.6
0.575
2.5   -
K-RY8x-3/120

120

3
0.118

1.1
0.043

9.7
0.382
14.6
0.575
3   1
K-RY8x-6/120

120

6
0.236

3
0.118
13
0.512
22.9
0.902
7.5   1,3
K-RY8x-1.5/350# 350 1.5
0.059
1.6
0.063
8.2
0.323
14.6
0.575
5   -
K-RY8x-3/350 350 3
0.118
1.2
0.047
9.7
0.382
14.6
0.575
5.5   -
K-RY8x-6/350 350 6
0.236
2.8
0.11
13.1
0.516
22.9
0.902
13   -
 

Ordering number

Nominal (rated) resistance

Dimensions [mm/inch]

Vmax 

Solder terminals are not required

Preferred types

Measuring grid

Carrier

Ω

a

b

c

d

 

K-RY6x-1.5/120K#

120

1.5
0.059

0.8
0.031

7.2
0.283
10.2
0.402
2   -

K-RY6x-1.5/120R#

120

1.5
0.059

0.8
0.031

8
0.315
13.5
0.531
2   -

 

 

Product Literature

題目/描述 語言
產品手冊
German
English
使用指南
German

Pre-wired Strain Gauges: Fast, Safe and Convenient to Use

Leave the welding to HBM and order pre-wired strain gauges. You no longer need to solder cables to the strain gauges, thus avoiding a potential source of error. HBM has set up a “fast lane” service for small orders, which helps provide you the strain gauge you need with the cable of required length within only 4 days.

Furthermore, new materials have been used in making the stranded connection wires more flexible and now easier to use. The temperature range has also been expanded to 150°C, opening up new applications. 

Advantages

An advantage only from HBM is the fluoropolymer-insulated stranded wire at the strain gauge which prevents the stranded wire from sticking during installation.

HBMshop 查看價格、庫存並獲得報價
馬上獲取報價!

向HBM銷售工程師詢問

請發給我:


開始詢價

向HBM銷售工程師詢問

請發給我:


開始詢價

單獨出價

技術諮詢

快速回應